Specific data for pH-ORP.600

C-PVC body flat surface electrode

This is the rugged version of the traditional flat electrodes with an improved selfcleaning effect. Installation and maintenance are easy due to the quick disconnect BNC connectors. Built into the electrode’s body is a sealed, gel-filled double junction reference design. This design provides an extra barrier against reference side contamination and allows the electrodes to be used in severe applications prolonging electrode life. The pH-responsive flat glass surface is placed in the center of the measuring surface and surrounded by the flat porous plastic reference junction providing an excellent sample contact. Version with amplified signal for long distance connection and metal pin to ground liquid. A wide range of installation accessories allows in line, submersion or hot tap installation
Specific data for pH-ORP.600
Reference system Category family series division subfamily Body Materiale/tipo di giunzione Reference solution Detection surface O-ring Connection Max working pressure at operating temperature
ORP650CD Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP PVC-C HDPE poroso/ D.J. KCl 3,5 M platino FKM Twist-Lock (BNC) 6,7 bar a 75 °C$(100 psi a 170 °F)
ORP650CDDA Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP PVC-C HDPE poroso/ D.J. KCl 3,5 M platino FKM Twist-Lock (BNC) 6,7 bar a 75 °C$(100 psi a 170 °F)
ORP655CD Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP PVC-C HDPE poroso/ D.J. KCl 3,5 M platino FKM Twist-Lock (BNC) 6,7 bar a 75 °C$(100 psi a 170 °F)
ORP660CD Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP PVC-C HDPE poroso/ D.J. KCl 3,5 M platino FKM Twist-Lock (BNC) 6,7 bar a 75 °C$(100 psi a 170 °F)
ORP660CDDA Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP PVC-C HDPE poroso/ D.J. KCl 3,5 M platino FKM Twist-Lock (BNC) 6,7 bar a 75 °C$(100 psi a 170 °F)
PH650CD Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP PVC-C HDPE poroso/ D.J. KCl 3,5 M membrana in vetro di pH piatto FKM Twist-Lock (BNC) 6,7 bar a 75 °C$(100 psi a 170 °F)
PH650CDDA Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP PVC-C HDPE poroso/ D.J. KCl 3,5 M membrana in vetro di pH piatto FKM Twist-Lock (BNC) 6,7 bar a 75 °C$(100 psi a 170 °F)
PH650CDHF Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP PVC-C HDPE poroso/ D.J. KCl 3,5 M membrana in vetro di pH piatto FKM Twist-Lock (BNC) 6,7 bar a 75 °C$(100 psi a 170 °F)
PH650CDLC Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP PVC-C HDPE poroso/ D.J. KCl 0,1 M membrana in vetro di pH piatto FKM Twist-Lock (BNC) 6,7 bar a 75 °C$(100 psi a 170 °F)
PH655CD Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP PVC-C HDPE poroso/ D.J. KCl 3,5 M membrana in vetro di pH piatto FKM Twist-Lock (BNC) 6,7 bar a 75 °C$(100 psi a 170 °F)
PH655CDHF Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP PVC-C HDPE poroso/ D.J. KCl 3,5 M membrana in vetro di pH piatto FKM Twist-Lock (BNC) 6,7 bar a 75 °C$(100 psi a 170 °F)
PH655CDLC Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP PVC-C HDPE poroso/ D.J. KCl 0,1 M membrana in vetro di pH piatto FKM Twist-Lock (BNC) 6,7 bar a 75 °C$(100 psi a 170 °F)
PH660CD Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP PVC-C HDPE poroso/ D.J. KCl 3,5 M membrana in vetro di pH piatto FKM Twist-Lock (BNC) 6,7 bar a 75 °C$(100 psi a 170 °F)
PH660CDDA Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP PVC-C HDPE poroso/ D.J. KCl 3,5 M membrana in vetro di pH piatto FKM Twist-Lock (BNC) 6,7 bar a 75 °C$(100 psi a 170 °F)
PH660CDHF Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP PVC-C HDPE poroso/ D.J. KCl 3,5 M membrana in vetro di pH piatto FKM Twist-Lock (BNC) 6,7 bar a 75 °C$(100 psi a 170 °F)
PH660CDLC Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP PVC-C HDPE poroso/ D.J. KCl 0,1 M membrana in vetro di pH piatto FKM Twist-Lock (BNC) 6,7 bar a 75 °C$(100 psi a 170 °F)

APPLICATIONS:

  • Water & Wastewater treatment
  • Pre-chlorination & de-chlorination
  • Neutralization systems
  • Water quality monitoring
  • Ozone treatment
  • Coolingtowers
  • Boiler systems
  • Bleach production
  • Pulp bleaching
  • Aquaculture
  • Fruit and vegetables washing
  • Textile Dye Process

MAIN FEATURES:

  • pH and ORP versions
  • Flat electrodes
  • Double junction technology
  • Large gel reference volume
  • High protection from process contamination
  • Easy and quick installation system
  • BNC connector
  • In line, submersion or hot tap installation
  • Low cost fittings
  • HF option (pH) for liquids with HF (max. 2%) inside
  • LC option (pH) on request for pure water (<100us >)

Downloads