MR SDR 11

Reducer, SDR 11

Reducer MR, SDR 11

  • Gas, water and H2
  • Maximum pressure: Gas 10 bar, Water 16 bar
  • Material: PE 100
  • Safety technology
  • Large insertion depth for good pipe routing (no holding devices required)
  • DVGW test mark: DV-8601AU2248 and DV-8606AU2249
  • FM Approvals Class: 1613 (d 90/63 - d 110/63 + d 110/90 - d 125/90 + d 160/110 - d 225/160)
Go back Data sheet

PE 100 SDR 11

Maximum permissible working pressure 16 bar (water) / 10 bar (gas)

Reference d1 d2 BX PU L t1 t2 D1 D2 B Weight kg
616824 20 16 70 2240 75 36 36 32/28 44 0,035
616452 32 16 80 2560 91 39 34 45/28 62 0,060
615386 32 20 80 2560 88 39 30 45/32 62 0,060
615502 32 25 70 2240 88 39 33 45/38 62 0,070
615387 40 20 60 1920 98 43 30 54/32 70 0,080
616751 40 25 120 1280 101 50 40 54/38 66 0,090
615388 40 32 50 1600 98 43 39 54/45 70 0,090
616752 50 25 130 960 107 52 39 66/38 77 0,120
612070 50 32 32 1024 110 49 39 68/45 82 0,140
612071 50 40 25 800 110 49 43 68/54 82 0,140
615389 63 32 18 576 125 55 44 82/45 96 0,210
615390 63 40 16 512 125 55 43 82/54 96 0,220
612072 63 50 16 512 125 55 48 82/68 96 0,230
616583 75 63 15 270 143 61 55 94/79 110 0,325
615391 90 50 15 270 160 69 49 117/68 129 0,470
615392 90 63 15 270 160 69 55 117/82 129 0,510
616582 90 75 15 270 159 67 63 113/94 127 0,505
615393 110 63 10 180 160 79 55 142/82 152 0,730
615693 110 90 8 144 180 79 69 140/115 152 0,900
615694 125 90 8 144 200 86 69 155/115 166 0,980
616510 125 110 16 128 202 95 70 157/137 172 1,300
615695 160 110 8 64 230 98 79 201/140 207 1,990
616511 180 125 1 60 275 108 74 214/155 230 2,600
616356 225 160 1 36 270 110 98 282/203 283 4,860

FRIALEN safety fittings can be fused with SDR11 - SDR17.6 pipes, with the exception of dimensions d 125/110 and d 180/125. These can be fused with SDR9 - SDR26 pipes. Other levels of SDR can be processed on request. Please note the mandatory labels directly on the product. DVGW test marks issued: DV-8601AU2248 and DV-8606AU2249

Areas of Application

The FRIALEN Electrofusion Reducer MR is applied for immediate pipe reduction within the pipe system.

Assembly Instructions

Fusing of pipe ends with the FRIALEN Electrofusion Reducers MR takes place by FRIALEN fusion – leakproof and longitudinally strong.

The pipe ends are prepared according to the general installation instructions (note “Assembly Instructions” for FRIALEN Safety Fittings for house connections and distribution pipes (remove oxide layer/clean).

Good reasons for using the FRIALEN Electrofusion Reducers MR:

  • Large coupler depth for ease of pipe guiding (no holding clamps required)

  • Extra wide fusion zones

  • Maximum stability through great wall thickness

  • Cold zones at the front side and in the middle of the coupler

  • Exposed heating coil for direct heat transmission to the pipe

  • Small annular gap for build-up of optimum joining pressure in the fusion zone

  • Touch proof electric contacts

  • Fusion indicator for visual fusion control

  • Durable batch marking

  • Individually wrapped for dirt protection

  • Additional barcode for tracing back the underground fitting (Traceability-Coding)

Downloads