PH6XX CD - C-PVC body flat surface electrode

C-PVC double junction Flat surface electrodes.

This line of FLS sensors constitutes the most robust model of traditional flat surface electrodes with a further enhanced self‑cleaning effect. Installation and maintenance are easy thanks to the fast BNC connection. A double‑junction reference with sealed gel has been integrated into the electrode body. This model enables an additional barrier against the contamination of the reference gel and allows the use of such electrodes in critical applications prolonging the duration of the working life. The pH glass is placed centrally in the flat surface and surrounded by a large porous plastic coupling that offers excellent contact between reference and liquid. Model with amplified signal is available for long‑distance connection and metal foot in ground liquid. The availability of a wide range of accessories allows for in‑line, flush‑mounted or immersion installation.

PH6XX CD - C-PVC body flat surface electrode
Reference Other description system Category family series division subfamily product.detail.attribute.Characteristics Operative Range product.detail.attribute.Reference solution product.detail.attribute.Detection surface Cable* Connection Installation Weight (gr.)
PH650CD * (Sold separately) Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP - - KCl 3.5 M flat pH glass membrane CN 653, CN 653 TC1 Twist-lock (BNC) MIFV20X05, MIMC20X05 100
PH650CDDA * (Sold separately) Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP Signal amplified Presence of stray currents KCl 3.5 M flat pH glass membrane CN 653, CN 653 TC1 Twist-lock (BNC) MIFV20X05, MIMC20X05 200
PH650CDHF * (Sold separately) Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP - Liquids with Hydrofluoric acid (max 2%) KCl 3.5 M flat pH glass membrane CN 653, CN 653 TC1 Twist-lock (BNC) MIFV20X05, MIMC20X05 100
PH650CDLC * (Sold separately) Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP - Liquids with lLiquids with low conductivity (10 μS/cm < conductivity < 100 μS/ cm) KCl 0.1 M flat pH glass membrane CN 653, CN 653 TC1 Twist-lock (BNC) MIFV20X05, MIMC20X05 100
PH655CD * (Sold separately) Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP With pressurized filling gel - KCl 3.5 M flat pH glass membrane CN 653 Twist-lock (BNC) WTF675, WTF675 TC1 100
PH655CDHF * (Sold separately) Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP With pressurized filling gel Liquids with Hydrofluoric acid (max 2%) KCl 3.5 M flat pH glass membrane CN 653 Twist-lock (BNC) WTF675, WTF675 TC1 100
PH655CDLC * (Sold separately) Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP With pressurized filling gel Liquids with low conductivity (10 μS/cm < conductivity < 100 μS/ cm) KCl 0.1 M flat pH glass membrane CN 653 Twist-lock (BNC) WTF675, WTF675 TC1 100
PH660CD * (Sold separately) Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP - - KCl 3.5 M flat pH glass membrane CN 653 Twist-lock (BNC) EG66P, MK660 100
PH660CDDA * (Sold separately) Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP Signal amplified Presence of stray currents KCl 3.5 M flat pH glass membrane CN 653 Twist-lock (BNC) EG66P, MK660 200
PH660CDHF * (Sold separately) Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP - Liquids with Hydrofluoric acid (max 2%) KCl 3.5 M flat pH glass membrane CN 653 Twist-lock (BNC) EG66P, MK660 100
PH660CDLC * (Sold separately) Automation system FLS Measurement and control Instrumentation Medición Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body Medición Electrodos de pH y ORP - Liquids with low conductivity (10 μS/cm < conductivity < 100 μS/ cm) KCl 0.1 M flat pH glass membrane CN 653 Twist-lock (BNC) EG66P, MK660 100

* (Sold separately)

APPLICATIONS:

  • Water and wastewater treatment
  • Prechlorination and dechlorination
  • Neutralisation systems
  • Water quality monitoring
  • Ozone treatment
  • Cooling towers
  • Boilers
  • Production of hypochlorite solutions
  • Cellulose pulp bleaching
  • Aquaculture
  • Fruit and vegetable washing
  • Drying of textile products

MAIN CHARACTERISTICS:

  • Availability of models for pH and ORP
  • Electrodes with flat measuring surface
  • Double coupling technology
  • High reference gel volume
  • High protection from process contamination
  • Quick and easy installation system
  • BNC connection
  • In‑line, flush‑mounted or immersion installation
  • Cost‑effective adapters
  • HF (pH) option for analysis on liquids containing hydrofluoric acid (max 2%)
  • LC (pH) option on request for low conductivity water (<100 μS/cm)
  • DA option for the presence of eddy currents or for long distances thanks to signal amplification

Downloads