SA

Spigot saddle, SDR 11

Spigot saddle SA SDR 11

  • Gas, water and H2
  • Working pressure: MOP (gas) 10 bar, PFA (water) 16 bar
  • Material: PE 100-RC
  • Saddle component with clamp
  • Tapping under pressure possible
  • Safety technology
  • DVGW test mark: DV-8601AU2248 and DV-8606AU2249.

Note:

For the pressure-free tapping, there is our drilling device FWAB.

For tapping under pressure, we recommend the drilling tool from Hütz & Baumgarten (www.huetz-baumgarten.de).

If required, please contact our hotline: +49 621 486-2325.

PE 100-RC SDR 11

Maximum permissible working pressure 16 bar (water) / 10 bar (gas)

Reference d1 d2 BX Pallet quantity d3 t h B1 Drilling Ø da Weight [kg]
612757 63 32 20 360 22 44 171 108 20 0,340
612759 63 50 20 360 37 55 184 108 36 0,370
615020 75 50 15 270 38 55 167 110 36 0,430
615285 90 32 20 160 21 44 207 155 20 0,710
612819 90 63 20 160 50 63 207 155 46 0,740
615334 110 32 12 96 24 51 238 178 20 0,820
615031 110 50 12 96 39 60 245 178 36 0,810
612760 110 63 12 96 49 81 263 178 46 0,860
615411 110 90 12 96 70 79 228 165 65 0,970
615087 125 32 12 96 21 44 248 190 20 0,950
612761 125 63 12 96 47 63 248 190 46 0,990
615412 125 90 12 96 70 79 243 185 65 1,080
615584 125 110 10 80 86 82 243 185 84 1,150
612886 160 32 8 64 21 44 289 223 20 1,440
612762 160 63 6 48 47 63 303 223 46 1,520
615413 160 90 2 36 70 79 303 223 65 1,640
615739 160 110 2 36 86 82 303 223 84 1,770
615585 160 125 2 36 98 87 303 223 95 1,890
612763 180 63 6 48 47 63 291 240 46 1,190
615414 180 90 2 36 70 79 312 241 65 1,820
615948 180 110 2 36 86 82 319 241 84 1,960
615740 180 125 2 36 98 87 324 241 95 2,110
612764 200 63 5 40 47 63 311 250 46 1,180
612765 225 63 5 40 47 63 336 255 46 1,210
615415 225 90 5 40 70 79 358 284 65 1,960
616044 225 110 5 40 86 82 368 284 84 2,080
616045 225 125 4 32 97 87 374 284 95 2,240
616046 225 160 4 32 125 98 385 284 123 2,580

Areas of Application

The FRIALEN-Spigot Saddles SA are used for tapping into unpressurised gas- and water pipes, as well as in pressure drainage. The connecting pipe is joined to the outlet pipe by using a FRIALEN coupler UB.

FRIALEN safety fittings are fusion-capable with PE pipes according to the specifications of the SDR pipe series on the barcode sticker/datasheet of the respective fitting. The minimum wall thicknesses specified in the standards EN1555-1, EN 12201-1 and ISO 4437 must be observed. 

Assembly Instructions

The fusion of the HD-PE distribution line and the HD-PE house connection line with FRIALEN-Spigot Saddles SA is carried out by FRIALEN-fusing – tight and longitudinally force-locking.

The saddle and the outlet are prepared according to the general assembly requirements (see assembly instructions: „FRIALEN safety fittings for sustainable pipes for gas, water networks and industrial systems made of PE“) (remove/clean oxide layer from pipe/spigot).

Tapping in a pressureless state up to Ø 46 mm, from Ø 65 bis Ø 123 mm swarf-reduced using the equipment from Hütz + Baumgarten (www.huetz-baumgarten.de).

For pipes in a non-pressurized state, SA fittings can be used as T-pieces with a reduced outlet.

For information on tapping into the main line under operating pressure, please contact our application engineering department.

Swarfless tapping up to Ø 46 mm, from Ø 65 to Ø 123 mm extremely swarfreduced by using the tapping equipment of Hütz + Baumgarten.

For pipes without pressure spigot saddles SA can be used as a T-piece with a reduced outlet.

For tapping the main line under operating pressure, please contact our Application Engineering Department.

Good reasons for using the FRIALEN-SA:

  • Compact construction
  • Open wire technology for direct heat transmission
  • Preassembled unit without loose parts
  • Nearly swarf-less tapping by using Hütz + Baumgarten equipment
  • Burr - and nearly ledge - free tapping for a maximum of hydraulic power
  • Leak-free drilling possible with shut-off valve
  • Extra wide fusion zone
  • Additional barcode for tracing back the fitting (Traceability-Coding)

Downloads